WEIQI ELECTRIC
WLTA905
1. Residual Current Transformer for Leakage Protection Measurement
2. Strong Insulation and Isolation Capability
3. Moisture- and Shock-Resistant Design
4. External Dimensions: 32.0 × 30.2 × 9.1 mm
Category:
Keywords:
WLTA905
Performance parameters
Order Example
External dimensions
Download Center
| Shell Material | PBT plastic | |
| Dielectric strength Leakage current: ≤1mA |
Between the primary winding and the secondary winding | 4kV/min |
| Insulation resistance | Between the primary winding and the secondary winding | Min 500 MΩ (500 VDC) |
| Welding Conditions | Welding methods | Manual welding |
| Welding temperature | (260 ± 10)°C | |
| Welding time | (3 ± 1) s | |
| Phase shift variation | / | |
| Phase-shift temperature variation | -30°C to 70°C Change ≤5' |
|
| Input current | Maximum Input Current | Output current | Maximum output current | Short-term thermal current | Load resistance (Ω) | Frequency of Use (kHz) |
| 30mA | 200mA | 60μA AC | 400μA AC | 600mA (≤30S) 10A (≤3S) |
120 (200mA) | 0.02–10 |

Product Documentation
Leave a message for inquiry
We highly value your feedback and inquiries. If you have any questions about our products or services, please fill out the form below, and we’ll get back to you as soon as possible.
Contact Us
Phone:+86-18907928352
Email:markhan@wqedq.cn
Address: Diaoyutai Industrial Park, Pengze County, Jiujiang City, Jiangxi Province
Official Account
Copyright © 2025 Jiangxi Weiqi Electric Appliance Co., Ltd.
Technical Support: 300.cn